GC Columns
Home¡¡¡¡GC Columns¡¡¡¡Support
HPLC Columns
Instruments¡¡¡¡Suppliers¡¡¡¡Ordering¡¡¡¡About us¡¡¡¡contact
AB-1
AB-1MS
AB-5
AB-5MS
AB-CarboWax 20M
AB-INOWAX
AB-FFAP
AB-35MS
AB-50+MS
AB-1301
AB-1701
AB-624
AB-PLOT Al2O3 "KCl"
AB-PLOT Al2O3 "S"
AB-PLOT Al2O3 "M"
AB-PLOT MoleSieve
AB-PLOT GasPro
AB-PLOT Q
AB-PLOT U
AB-Blood Alcohol
Column
AichromBond-1
AichromBond-AQ
AichromBond-2
AichromBond-P
AichromBond-AQ C18
Guard Column
Aichrom SI
Aichrom NH2
Aichrom CN
 
 

AichromBond LC Column Products for Specific Applications

¡ñ AichromBond-1
¡ñ AichromBond-AQ
¡ñ AichromBond-2
¡ñ AichromBond-P
¡ñ AichromBond-AQ C18 Guard Column
¡ñ Aichrom SI
¡ñ Aichrom NH2
¡ñ Aichrom CN
AichromBond-1 C18
¡ñ strongly hydrophobic ( among the most hydrophobic phases)
¡ñ Highest inertness, method development optimization
¡ñ Good peak shape for basic, acidic and neutral compounds
¡ñ Better high volume injection tolerance ( peaks on Luna start to broadening at 20 ul inj)
¡ñ High performance over a wide pH range¡ª1.5~10.0
¡ñ Particle size from 2.1um to 4.6um
¡ñ Long lifetime with extra dense bonding and double endcapping
¡ñsimilar selectivity to Luna C18, and even closer to Supeco Discovery C-18
Column Specifications
Bonded Phase Carbon Load Pore Size Surface Area pH Range Endcapped
AichromBond-1 22% 100A 380 m2/g 1.5~10.0 Double
 
Order Information
Description Size(mm) Particle Size(um) P/N
Analytical
150mm¡Á4.6 5 1805071-150
Analytical 250mm¡Á4.6 5 1805071-250
Narrow Bore 150mm¡Á2.1 5 1805072-150
Narrow Bore 250mm¡Á2.1 5 1805072-250
 
Performance Comparison:
¡ñ Large volume injection and least peak tailing for bases

 
 
Sample: Uracil, 2,3-dihydroxynaphtlene, Propanolol, Naphtlene, Amitriptyline
Column: AichromBond-1 C18, 4.6 x 150 mm, 5 um particle size
Mobile phase: 10 mm sodium phosphate buffer (pH=7)/AC N ( 25:75)
Temperature: 30 oC
Detection: UV 254 nm
Flow: 1 mL/min.
 
¡ñ Low Pressure
 
Sample: 1. Uracil, 2. 2,3 dihydroxy naphtlene, 3. Propanolol, 4. Naphtlene, 5. Amitritypline
Injection: 5 uL
Column: 4.6 mm x 150 mm, 5 um
Mobile phase: 10 mmol sodium phosphate buffer (pH=7)/Methanol = 15:85
Flow: 1 mL/min
Temperature: 30 oC
Detection: UV 254 nm
 
AichromBond-AQ C18
¡ñ Inertness: it is one of most base-friendly columns, comparable with Xterra and even better than Inertsil, is far better than Kromasil and Hypersil.
¡ñ Efficiency: the best for polar compounds at any pH.
¡ñ Large volume injection: maintain very high efficiency even if the injection volume is exceptional large.
¡ñ 100% water compatible: very unique for a universal C18 column; far better peak shape, retention and efficiency than those so-called high aqueous ¡°AQ¡± columns.
¡ñ Low pH Stability (pH=1.5): next to the Zorbax SB C18, it has better stability than most of popular brand columns on the market, and is far better than any domestic column at low pH.
Column Specifications
Bonded Phase Carbon Load Pore Size Surface Area pH Range Endcapped
AichromBond-AQ 19% 100A 380 m2/g 1.5~10.0 Single
 
Order Information
Description Size(mm) Particle Size(um) P/N
Analytical
150mm¡Á4.6 5 1805AQ1-150
Analytical 250mm¡Á4.6 5 1805AQ1-250
Narrow Bore 150mm¡Á2.1 5 1805AQ2-150
Narrow Bore 250mm¡Á2.1 5 1805AQ2-250
 
Performance Comparison:
¡ñ Inertness and efficiency comparison
Sample: uracil, toluene, doxepin , amitriptyline
Column: AichromBond AQ C18, 4.6 x 150 mm, 5 um particle size
Mobile phase: 10 mM sodium phosphate (pH=7) in 60% ACN
Flow: 1 mL/min.
Temperature: 30¡æ
¡ñ Large volume injection

Large Volume Injection (injection volume =100 uL, )
Sample: 4-methoxybenzenesulfonamide, 10 ug/mL in MeOH/Water (1:1)
Column: AichromBond AQ C18, 4.6 x 150 mm, 5 um particle size
Mobile phase: MeOH/Water
Flow: 1mL/min.
Temperature: 30¡æ

 
¡ñ Compatible to 100 water mobile phase
Sample: Uridine
Column: AichromBond AQ C18, 4.6 x 150 mm, 5 um
Column dimension: 4.6 x 150 mm
Mobile phase: 100% water
Flow: 1mL/min.; The flow was stopped once for 5 minutes during the testing period for each column.
Temperature: 30¡æ
 
¡ñ Stability at pH=1.5
Sample: Uracil, Doxepin, Amitriptyline, Toluene.
Column: AichromBond AQ C18, 4.6 x 150 mm, 5 um
Mobile phase: TFA (0.25%, pH=1.5) in 60% acetonitrile
Flow: 1 mL/ min
Temp: 40¡æ