GC Columns
Home
GC Columns
 Support  HPLC Columns   Instruments  Suppliers  Ordering  About us  contact
AB-1
AB-1MS
AB-5
AB-5MS
AB-CarboWax 20M
AB-INOWAX
AB-FFAP
AB-35MS
AB-50+MS
AB-1301
AB-1701
AB-624
AB-PLOT Al2O3 "KCl"
AB-PLOT Al2O3 "S"
AB-PLOT Al2O3 "M"
AB-PLOT MoleSieve
AB-PLOT GasPro
AB-PLOT Q
AB-PLOT U
AB-Blood Alcohol
Column
AichromBond-1
AichromBond-AQ
AichromBond-2
AichromBond-P
AichromBond-AQ C18
Guard Column
Aichrom SI
Aichrom NH2
Aichrom CN
 
  GC Columns
 Polysiloxane Based Stationary Phases
AB-1
  Similar phases: DB-1, HP-1, Ultra-1, SPB-1, RTX-1, CP-Sil 5CB, BP-1, ZB-1, AT-1, MDN-1, OV-1, OV101
AB-1MS
  Similar phases: HP 1MS, DB 1MS, BPX-1, AT 1MS, ZB-1, Rtx-1, CP-Sil 5 CB
AB-5
  Similar phases: DB-5, HP-5, Ultra-5, SPB-5, RTX-5, CP-Sil 8CB, BP-5, ZB-5, AT-5, MDN-5, OV-5, SE-52, SE-54
AB-5MS
  Similar phases: HP-5MS, DB-5MS, BPX-5MS, AT-5MS, Rtx-5MS, CP-Sil 8 CB
AB-35MS
  Similar Phases: HP-35MS, DB-35, BPX-35, AT-35, Rtx-35, SPB-35
AB-50+MS
  Similar Phases: HP-50+, DB -7, DB-17MS, BPX-50, AT-50, Rtx-50, SPB-50
AB-1301
  Similar Phases: HP-1301, DB-1301, BP-10, Rtx-1301
AB-1701
  Similar phases: DB 1701, ZB 1701, BP-10, Rtx-1701, CP-Sil 19 CB
AB-624
  Similar phases: DB-624, ZB-624, AT-624, Rtx-624, CP-624
AB-VOC
  Similar phases: DB-VRX, HP-VOC, Rtx-VRX, HP-624
 
 Polyethylene Glycol (PEG) Phases
Abel offers three types of PEG columns: AB-INOWAX, AB-FFAP and AB-CarboWax 20M, based on the characteristics of the PEG stationary phases, to meet various applications.
AB-INOWAX
  Similar Phases: HP-INNOWax, DB-WAX, DB-WAXetr, SupelcoWAX 10, CP-WAX 52 CB, CB-WAX, Stablilwax, BP-20, 007-CW, AT-Wax, Rtx-Wax, ZB-Wax, HP-20M
AB-FFAP
  Similar Phases: HP-FFAP, DB-FFAP, CB-WAX 58 (FFAP) CB,
Stabilwax-DA, BP-21, 007-CW, AT-100
AB-CarboWax 20M
 
 AB-PLOT Columns
AB-PLOT Al2O3 "KCl"
  Replacement: HP-PLOT Al2O3/"S", GS-Alumina, CP-Al2O3/Na2SO4 PLOT, ZB-Alumina, RT-Alumina
AB-PLOT Al2O3 "M"
  Replacement: HP-PLOT Al2O3/"M", GS-Alumina, ZB-Alumina
AB-PLOT MoleSieve
  Replacement: HP-PLOT Molesieve, CP-PLOT MolSieve
AB-PLOT GasPro
  Replacement: GS-GasPro, CP-Silica PLOT
AB-PLOT Q
  Replacement: HP-PLOT Q, GS-Q, CP-PoraPLOT Q HT, Supel PLOT Q, Rt-Q, ZB-PLOT Q
AB-PLOT U
  Replacement: HP-PLOT U, CP-PoraPLOT U
AB-Blood Alcohol Column
 
 Fused Silica Tubing
Undeactivated Tubing
  Bare fused silica tubing are commonly used as sample transfer line where inertness is not required. It can also be used as raw tubing for preparation of customized column. All bare fused silica tubing is offered as pre-wrapped onto a 6inch diameter cage.
Deactivated Tubing
  Deactivated fused silica tubing is commonly used as retention gap and guard column or sample transfer line. They can prolong analytical column life, as they trap most "dirty" or undesired compounds. Our standard deactivation method is methyl siloxane deactivation. We also can offer other deactivation methods upon requesting. All deactivated fused silica tubing is offered as pre-wrapped onto a 6inch diameter cage.
 
 
 
 GC Column selection and Applications
GC Columns stationary phase applications guide
United States Pharmacopoeia (USP GC Phases)
Environmental/EPA Methods
ASTM Methods(Page1)  (Page2)   (Page3)
Chemicals Environmental
Food and flavor Petrochemical
 
 AB-5MS and PONA
 
  AB-5MS
  PONA
 New GC column
 Column Care
 
 
 
 
 

Click to get the direction

 
  Ordering
How to Place Orders Catalog Number Guide
Terms and Conditions Order Form