GC Columns
Home¡¡¡¡GC Columns
Support
¡¡HPLC Columns¡¡¡¡ Instruments¡¡¡¡Suppliers¡¡¡¡Ordering¡¡¡¡About us¡¡¡¡contact
AB-1
AB-1MS
AB-5
AB-5MS
AB-CarboWax 20M
AB-INOWAX
AB-FFAP
AB-35MS
AB-50+MS
AB-1301
AB-1701
AB-624
AB-PLOT Al2O3 "KCl"
AB-PLOT Al2O3 "S"
AB-PLOT Al2O3 "M"
AB-PLOT MoleSieve
AB-PLOT GasPro
AB-PLOT Q
AB-PLOT U
AB-Blood Alcohol
Column
AichromBond-1
AichromBond-AQ
AichromBond-2
AichromBond-P
AichromBond-AQ C18
Guard Column
Aichrom SI
Aichrom NH2
Aichrom CN
 
 
¡¡New GC Columns(1)

AbelBonded (AB) GC columns are developed and made in USA by ex-column tech gurus from brand name company with proprietary manufacturing process. AB columns not only replicate the performances of the brand name products, but also have improved the long-time known problems of the brand name ones. AB GC columns are offered at competitive prices to brand name products. With these features, AB GC columns are really best values products and gainful replacements of brand name products.

¡¡  Replicating performances

Column performances are characterized as stationary phase, column selectivity and retention time. AB GC columns are reengineered and made by the same stationary phases as that used by the brand name products. With stringent process control AB GC columns replicate column selectivity and retention times of brand name products for seamless column switching. Table I to II illustrate the performance comparisons of the most popular stationary phases: AB-5MS and AB-Inowax vs the brand name ones.

Table I AB-5MS Comparisons at 135¡æ
Column Brand

AB-5MS

Brand H-5MS

Brand D-5MS
RI (Methyl Decanoate)
1324.0¡À1.0
1324.2 1323.7
RI (Acenaphthylene)
1462.0¡À1.0
1462.1 1462.1
RI (1-Dodecanol)
1473.5¡À1.0
1474.2
1473.7
K'Pentadecane)
6.0¡À0.6
5.9
6.4
K'Undecane)
0.7
0.69
0.76
Temperature Limits -60 to 325/350¡æ -60 to 325/350¡æ -60 to 340/360¡æ


Table II AB-Inowax Comparisons at 130¡æ

Column Brand

AB-Inowax

Brand H-Innowax

AB-CarboWax (true PEG column)

RI (Methyl Undecanoate)
1715.8 1716.2

1699.6

RI (1-Decanol)
1779.8
1779.7

1752.1


K'Tetradecane) 0.51 0.54
K'2,6-Dimethylphenol)
9.31
9.81
50 to 220¡æ
Temperature Limits
40 to 260/280¡æ
50 to 260/280¡æ
Crosslinked and Bonded Yes Yes No
Fig 1 and 2 also graphically show such close performance comparison for these two popular stationary phase columns. Fig 1 is the graphic comparison of AB-5MS to Brand H-5MS, and Fig 2 is the comparison of AB-Inowax to brand H-Innowax.
 
Based on these comparisons, it can conclude that AB GC columns have essentially identical performances to the brand name ones.
New GC Columns(2)